The difference between a $300 pipe repair and a $3,000 drywall-and-remediation job is often just whether the leak was found before or after excessive wall opening. Our detection service in Cuba uses the same methods utilities and insurance adjusters rely on โ to pinpoint the failure before anything is cut.

No single detection method works for every leak scenario. Our techs are trained on four distinct approaches and select the right tool โ or combination โ based on pipe type, building construction, and leak characteristics.
Pressurized supply line leaks create a low-frequency sound as water escapes the pipe and contacts surrounding soil or structure. Our amplified listening devices filter background noise so we can triangulate the loudest point โ often to within 6โ12 inches of the actual break, through concrete slabs or behind drywall.
Particularly effective inside insulated wall cavities and for finding the extent of moisture spread beyond the immediate leak point โ telling us not just where the pipe is failing but how far the moisture has already traveled.
Pressure decay testing is the standard by which we confirm a leak is present before committing detection equipment time. A rapid drop vs. a slow one also indicates the approximate size of the escape point.
Tracer gas is the method of last resort for the most challenging cases. It adds setup time but finds leaks that acoustic and thermal methods alone can't conclusively locate.
Hidden leaks occur in different locations throughout a property โ each requiring a slightly different detection approach. Here's how we handle the most common scenarios in Cuba, NM.
Supply lines running under or through the concrete slab fail from corrosion, shifting, or manufacturing defects โ and the leak is invisible from the surface but audible to acoustic equipment. We walk the floor on a grid pattern, map the loudest detection points, and triangulate to a specific floor location, typically within a square foot. Confirmed slab leak location is documented with marked coordinates for the repair crew.

Wall and ceiling leaks are often traced by following a visible stain to its apparent high point โ but visible damage can be several feet from the actual pipe failure due to how water travels down framing members. Thermal imaging reveals the wet zone accurately, and acoustic equipment confirms the pipe location within the wall cavity.
We also perform leak correlation surveys for longer line runs, using two listening points to triangulate the failure location mathematically.
Irrigation system leaks in main supply and lateral runs are found by isolating zones with the irrigation controller and pressure-testing each zone individually. Zone-by-zone testing narrows the failure to the smallest possible section.

Insurance claims for water damage from hidden leaks typically require documentation that the leak was not visible or detectable without specialized equipment. Our detection report includes: pressure test results confirming active water loss, detection method used, thermal imagery or acoustic mapping showing leak location, and technician certification information.
Commercial buildings have complex pipe networks where a supply or drain leak can go undetected through multiple floors before surfacing. We approach commercial detection systematically โ zone-by-zone pressure isolation, thermal scan of suspect surfaces, and acoustic confirmation.
Finding a hidden leak isn't a single step โ it's a protocol that combines water loss confirmation, zone isolation, and targeted detection in sequence.
This step confirms we're looking for a real leak rather than a meter error or normal appliance cycling.
Zone isolation turns "there's a leak somewhere in the house" into "the leak is on the hot side supply between the water heater and the master bath."
We document findings with thermal images and note detection readings at multiple grid points to triangulate the strongest signal.
Insurance-formatted reports are available for claims submission at the same standard โ no additional cost.

High-efficiency home with a slow leak โ about 1.5 gallons per hour. The tech used tracer gas after pressure testing confirmed the loss but acoustic detection couldn't localize it clearly. Gas detection found the escape at a micro-fitting under the slab in the utility corridor. Impressive work for a very difficult leak to find.
Our insurance company required professional leak detection documentation before approving the claim. Masters Plumbing Service's written report with pressure test data and thermal imagery was exactly what the adjuster needed. Claim approved. The detection cost was covered as part of the claim.
Commercial building with elevated water costs for six months. Masters Plumbing Service ran zone-by-zone pressure isolation across four floors, narrowed the loss to the third-floor kitchen supply branch, and located the failure with thermal imaging at a concealed valve body in the ceiling. No damage to the finished ceiling.
Our detection technicians are equipped with acoustic, thermal, and tracer gas tools for the full range of leak scenarios found in Cuba, NM homes and commercial properties.

Masters Plumbing Service's detection team finds hidden leaks in Cuba homes and commercial properties using equipment that eliminates guesswork. The detection appointment pays for itself the moment it prevents one unnecessary wall opening.
๐ Call +1-844-833-0201 Now